Nuclear Radiation Detection - SVG 2

Bruker Daltonics Inc.
Dr. Norbert Klöpper

By Dr. Norbert Klöpper, Product Manager, Bruker Daltonics, Bruker Daltonics Inc.

View Author Profile

The SVG 2 is a hand-held, hardened micro-processor controlled radiation detector, based on state-of-the-art semiconductor technology.

gamma and neutron radiation detectionEquipped with integrated sensors for gamma and neutron radiation detection, an external personal dosimeter, and an external /-probe.

Additional probes, like an extended /--probe or external vehicle g-probes, can be connected. The base instrument is easy to handle and is particularily distinguished by its low weight and power consumption. Not only the current -dose rate but also the integrated -dose over a certain time can be displayed. Moreover, the initial and assimilated dose of n- and -radiation is measured by an internal dosimeter - even if the instrument is shut off. Alarm thresholds for all the modes are adjustable.

For the mounted use in vehicles, the SVG 2 will be connected to two external g-probes, which are permanently attached on both sides of the vehicle. Due to its unique design, the SVG 2 is capable of performing any thinkable detection task in a nuclear contaminated terrain.

Technical Data

Basic Unit

  • Dimensions (WxHxL): 196x96x122 mm
  • Weight incl. batteries: 1.7 kg
  • Power Supply: 3x1.5 V (>90 hours of operation) and/or via vehicle (10-32 V DC)
  • Programmable thresholds for optical and acoustic alarm
  • EMP and TREE protected, water tight
  • Decontaminable by complete immersion
  • Measurement ranges:

    -radiation: 70 keV...1.5 MeV
    -dose rate: 0.5 µGy/h... 2000 cGy/h
    -dose: 0-2000 cGy

Internal dosimeter

  • Dimensions (WxHxL): 196x96x122 mm
  • Measurement ranges:
    -radiation: 0.1...3 MeV
    - and n-dose: 0 cGy...2000 cGy (also measured when the instrument is shut off)
  • Power Supply: 3x1.5 V (>90 hours of operation) and/or via vehicle (10-32 V DC)
  • Programmable thresholds for optical and acoustic alarm
  • EMP and TREE protected, water tight
  • Decontaminable by complete immersion

External a/b-g-probe

  • Dimensions (WxHxL): 196x96x122 mm
  • For measurement of surface activity and contamination of liquids. Separate and combined measurement of -, - and g-radiation.
  • Measurement ranges:
    -, -radiation: 0...350 kCps (0...550 kBq/cm2)
    -radiation: 70 keV...1.5 MeV
    -dose rate: 0.5 µGy/h... 200 cGy/h

External vehicle -probes

  • Measurement ranges same as base unit.
Dr. Norbert Klöpper

Author Information - Dr. Norbert Klöpper

Product Manager, Bruker Daltonics

Dr. Norbert Klöpper was born in 1970 in Leipzig, Germany. During his studies he specialized in physical chemistry with emphasis on spectrometric methods on liquid crystals and biological applications. He spent two years in the German steel industry as a project manager. He joined Bruker Daltonics as a developer in 2000. He is the leader of the APSIS project and is product manager for the entire CBRN product line.